Security module SMCP30
Productparameters:RyanSafetyModule-SpecialSafetyControlModuleforPressMachines,Lowcost,multifunctional,simplewiring,easytoachievecomplexsafetycontrolofpressmachines!1、BasicIntroduction1.1Compliantwiths...
Product parameters:
Ryan Safety Module - Special Safety Control Module for Press Machines,
Low cost, multifunctional, simple wiring, easy to achieve complex safety control of press machines!
1、Basic Introduction
1.1Compliant with standards
This safety module, including emergency stop monitoring, safety door monitoring, safety grating monitoring, and cam detection, meets the requirements of EN ISO13849-1 PL e.
Two handed button monitoring meets the requirements of BS EN574-1996 IIIC.
1.2 use to
The wiring is simple and easy to operate, and the safety module is mainly used for safety control of machine tools and bending machines:
Multi way emergency stop monitoring.
2-way safety door or safety hydrant monitoring.
2-way safety grating monitoring.
1 way dual hand monitoring, 1 way foot monitoring.
1-way cam signal detection.
Detection of overtravel and broken shaft signals.
Safety dual valve detection.
Cam switch detection.
Inching, single shot, continuous function.
Safety circuit in accordance with EN60204-1.
Comply with the requirements of GB 27607-2011 and GB 28243-2012 standards.
1.3 Characteristics
Raster operation with“automatic”and“Forced manual”Reset mode.
Relay contact output: 2 sets of normally open (N/O) safety contact outputs, and 1 set of normally closed (N/C) auxiliary contact outputs.
Ordinary transistor output (emergency stop, grating, safety door, both hands).
Provide feedback control loop for monitoring external contactors/relays (dual valve).
Equipped with input and output status indicator lights.
Power on input port self check function.
Alarm:
①Power on self test, port short circuit alarm
②Overtravel alarm
③Axis breakage alarm
④Cam switch abnormal alarm
This security module meets the following security requirements:
The circuit is equipped with self monitoring redundant circuits and uses a dual MCU control system.
Even if one component is damaged, the safety function remains effective.
The safety function of the safety module can be automatically detected by correctly opening and closing during each switch cycle.
Cross short circuit detection function.
Main technical parameters:
1、voltage:24V DC/AC;
2、consumption:6.5W(Without load);
3、output:2N/OSafety contact output 1N/CAuxiliary output 4PNP transistor output;
4、2 reserved functions for auxiliary output;
5、Switching capacity: safety contacts are AC-15, 5A/250V DC-13, 6A/24V Transistor PNP output 0.8A 24VDC;
6、Pickup time:<50ms;
7、RELEASE:<20m;
8、Hand synchronization time:0.5S;
9、anti-jamming performance:IEC61131-2。